Dicionario de datos

ID
Sewer Pressurized Asset Identification
Tipo
text
Descrición

Identification number assigned by the City of Toronto

ID
Sewer Pressurized Upstream Maintenance Hole
Tipo
text
Descrición

Identification number of upstream maintenance hole

ID
Sewer Pressurized Downstream Maintenance Hole
Tipo
text
Descrición

Identification number of downstream maintenance hole

ID
Sewer Pressurized Twin Number
Tipo
int4
Descrición

Distinguishes pipes that have the same upstream and downstream maintenance holes.

ID
Sewer Pressurized Flow Type
Tipo
text
Descrición

Type of medium flowing in the sewer (SAN - Sanitary, Storm - Stormwater, Combined - Combined, CSO - Combined Sewer Overflow, SCSO - Storm Plus CSO)

ID
Sewer Pressurized Structure Type
Tipo
text
Descrición

Sewer main structure type (FM - forcemain, PSL - Pressure Sewer Line)

ID
Sewer Pressurized Location Description
Tipo
text
Descrición

Address or location description

ID
Sewer Pressurized Owned By
Tipo
text
Descrición

Ownership group of the pressurized sewer

ID
Sewer Pressurized Managed By
Tipo
text
Descrición

Maintenance group of the pressurized sewer

ID
Sewer Pressurized Install Date
Tipo
timestamp
Descrición

Approximate construction date

ID
Sewer Pressurized Diameter
Tipo
int4
Descrición

Pipe diameter (millimetres)

ID
Sewer Pressurized Material
Tipo
text
Descrición

Pipe material (ABS - ABS Plastic, AC - Asbestos Cement, BMP - Brick Masonry, BR - Brick, CCYL - Concrete Cylinder Pipe, CI - Cast Iron, CICL - Cast Iron Cement Lined, CMP - Corrugated Metal, CONC - Concrete - Cast-In-Place, COP - Copper, CP - Concrete (Non-Reinforced), CR - Prestressed Concrete, CT - Clay Tile, DICL - Ductile Iron Cement Line, DIP - Ductile Iron, EARGEO - Earth & Geotextile, FRP - Fiberglass Reinforced, GP - Galvanized Pipe, GRC - Glass Reinforced Cement, HDPE - High Density Polyethylene, LEAD - Lead, OTH - Other, PCCP - Pre-Stressed Concrete Cylinder, PE - Polyethylene, PP - Polypropylene, PSC - Plastic/Steel Composite, PVC - Polyvinyl Chloride, PVCO - Molecular Oriented Polyvinyl Chloride, RPM - Reinforced Plastic (Truss), SP - Steel, SPCL - Steel Pipe Cement Lined, TRR - Transite Ringtite, TRS - Transite Simplex, TTE - Transite, UNK - Unknown, VCP - Vitrified Clay, WD - Wood)

ID
Sewer Pressurized Main Shape
Tipo
text
Descrición

Pipe cross-sectional shape (e.g. circular)

ID
Sewer Pressurized Measured Length
Tipo
float8
Descrición

Approximate span of the selected pipes (metres)

ID
Sewer Pressurized Trunk Sewer
Tipo
text
Descrición

Yes or No label denoting a Trunk Sewer

ID
Sewer Pressurized Trunk Name
Tipo
text
Descrición

Identification name assigned by the City of Toronto

Información adicional

Campo Valor
Última actualización de datos 30 de xuño de 2025
Última actualización de metadatos 3 de xuño de 2026
Creado 30 de xuño de 2025
Formato GeoJSON
Licenza License not specified
Datastore activeTrue
Datastore cache{'CSV': {'4326': 'c2face06-6d83-4f8f-b34d-b5decbcec62c', '2952': '19971b18-e834-4932-8efc-54699f8de101'}, 'SHP': {'4326': '2e98112a-2c54-4cf8-936e-d9b99f6961fa', '2952': '3bd6e89c-244d-4f51-ae6b-248338c040fc'}, 'GPKG': {'4326': '86b4c735-a2c8-4985-b408-5f959daccb82', '2952': '6e201028-25d9-411a-94d2-d6218f502e19'}, 'GEOJSON': {'4326': 'f3c90988-a721-4cab-aab7-a3efa52dd2f7'}}
Datastore cache last updatehai 1 mes
Extract jobAirflow: Integration Pipeline sewer-pressurized-mains
Has viewsTrue
Idbde72afc-16c8-4c19-a6c3-3114c3de7b35
Is previewTrue
Package id209b035f-93fa-4f72-827c-17495d75ed99
Position0
Record count309
Stateactive
Url typedatastore
Vertex count3.411
Extract Job Airflow: Integration Pipeline sewer-pressurized-mains
Is Datastore Cache File?
Datastore Cache
  1. CSV
  2. SHP
  3. GPKG
  4. GEOJSON
Datastore Cache Last Updated
Datastore resource's ID