{"help": "https://ckan0.cf.opendata.inter.prod-toronto.ca/tr/api/3/action/help_show?name=datastore_search", "success": true, "result": {"include_total": true, "limit": 100, "records_format": "objects", "resource_id": "a96c0ba4-3026-402b-b09d-5b1268b8f810", "total_estimation_threshold": null, "records": [{"_id":1,"PERMIT_NUM":"20 139970 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"5","STREET_NAME":"MABELLE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30058043","WARD_GRID":"W0321","APPLICATION_DATE":"2020-04-28","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-09","STATUS":"Approved","DESCRIPTION":"APPLICATION TO USE GRADE TP304 SCH 10 STAINLESS STEEL (SS) PIPE AS ALTERNATIVE TO TYPE L COPPER FOR DOMESTIC WATER MAIN RISER FOR ADDED SAFETY OF HIGHER WORKING PRESSURE RATING OF SS PIPE (LISTED @ 1000 PSIG) COMPARED TO TYPE L COPPER (LISTED @ 504 PSIG). SS PIPE PROPOSED TO BE INSTALLED USING VICTAULIC RIGID COUPLING STYLE 89 OR WELDED JOINT FOR JOINT FITTINGS.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":2,"PERMIT_NUM":"20 137886 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"57","STREET_NAME":"BROCK","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M6K","GEO_ID":"776820","WARD_GRID":"S0435","APPLICATION_DATE":"2020-04-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-14","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application to provide 65 mm standpipe system hose valve connections in general conformance with the 2015 National Building Code (NBC) and the 2013 Edition of NFPA 14, `Standard for Installation of Standpipe and Hose System¿ (as referenced by the NBC) in this fully sprinklered building.  The 65 mm hose connections will be provided in lieu of hose stations (38 mm  hose valves, 38 mm hose and nozzle) required by the 2012 Ontario Building Code.  The standpipe system and hose connections will be located within exit stair enclosures.  ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":3,"PERMIT_NUM":"20 134971 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"0","STREET_NAME":"SHEPPARD","STREET_TYPE":"AVE","STREET_DIRECTION":"W","POSTAL":"   ","GEO_ID":null,"WARD_GRID":"N1827","APPLICATION_DATE":"2020-04-17","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-07","STATUS":"Approved","DESCRIPTION":"Alternative Solution to permit the use of 65 mm standpipe hose valves in exist stairs and floor areas in lieu of fire hose cabinets containing 65 mm and 38 mm hose valves with 38 mm fire hoses within the building ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":4,"PERMIT_NUM":"20 154901 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"60","STREET_NAME":"SHUTER","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5B","GEO_ID":"7642396","WARD_GRID":"S1332","APPLICATION_DATE":"2020-06-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-28","STATUS":"Cancelled","DESCRIPTION":"This alternative solution proposal has been prepared to address the required rated wall assemblies serving exit stair C on the 4th and 5th levels of the building. Currently, it is understood that glazed assemblies provided within the exit stair are provided with insulated metal panels (I.E., no vision glass from the stair well). However, based on the correspondence with Menkes, it is understood that the metal panels provided within the exit stair shaft are not provided with a fire resistance rating. As such, the openings provided are considered as unprotected openings. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":5,"PERMIT_NUM":"20 140523 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"620","STREET_NAME":"DUNDAS","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"20362101","WARD_GRID":"S1330","APPLICATION_DATE":"2020-04-29","ISSUED_DATE":null,"COMPLETED_DATE":"2021-08-06","STATUS":"Cancelled","DESCRIPTION":"Alternative solution for standpipes - associated with File 19 153651 BLD","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":6,"PERMIT_NUM":"20 146786 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"502","STREET_NAME":"ADELAIDE","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"7930863","WARD_GRID":"S1029","APPLICATION_DATE":"2020-05-20","ISSUED_DATE":null,"COMPLETED_DATE":"2021-11-22","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application for the storage rooms (containing up to 4 storage lockers in each room) located in the southeast corner of the below-grade parking levels P3 and P2 are directly accessed via a  single access stair (Stair A).","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":7,"PERMIT_NUM":"20 151599 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"85","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115220","WARD_GRID":"W0533","APPLICATION_DATE":"2020-06-02","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-12","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution is the sequence of the fire alarm signaling in a single stage fire alarm system.  Sentence 3.2.4.4.(1) requires a single stage fire alarm system, upon the operation of any manual pull station or fire detector, to cause an alarm signal to sound on all audible signal devices in the system.  This Alternative Solution is to provide a modified single stage fire alarm system.  See attached sequence of Fire Alarm System.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":8,"PERMIT_NUM":"20 151603 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"125","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115223","WARD_GRID":"W0533","APPLICATION_DATE":"2020-06-02","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-12","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution is the sequence of the fire alarm signaling in a single stage fire alarm system.  Sentence 3.2.4.4.(1) requires a single stage fire alarm system, upon the operation of any manual pull station or fire detector, to cause an alarm signal to sound on all audible signal devices in the system.  This Alternative Solution is to provide a modified single stage fire alarm system.  See attached sequence of Fire Alarm System.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":9,"PERMIT_NUM":"20 146678 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"65","STREET_NAME":"KING","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"8313396","WARD_GRID":"S1338","APPLICATION_DATE":"2020-05-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-29","STATUS":"Approved","DESCRIPTION":"Alternative Solution for proposed exit stair G discharges through the retail vestibule G22 of the external parcel 71 King St. which would not be in compliance with the literal requirements of OBC sentence 3.4.4.2 (2), as more than one exit will lead through a lobby within the building","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":10,"PERMIT_NUM":"20 153038 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"44","STREET_NAME":"DUNFIELD","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4S","GEO_ID":"797765","WARD_GRID":"S1228","APPLICATION_DATE":"2020-06-05","ISSUED_DATE":null,"COMPLETED_DATE":"2021-01-20","STATUS":"Approved","DESCRIPTION":"APPLICATION TO USE GRADE TP304 SCH 10 STAINLESS STEEL (SS) PIPE AS ALTERNATIVE TO TYPE L COPPER FOR DOMESTIC WATER MAIN RISER FOR ADDED SAFETY OF HIGHER WORKING PRESSURE RATING OF SS PIPE (LISTED @ 1000 PSIG) COMPARED TO TYPE L COPPER (LISTED @ 504 PSIG). SS PIPE PROPOSED TO BE INSTALLED USING VICTAULIC RIGID COUPLING STYLE 89 OR WELDED JOINT FOR JOINT FITTINGS.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":11,"PERMIT_NUM":"20 154949 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"17","STREET_NAME":"DUNDONALD","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M4Y","GEO_ID":"9879946","WARD_GRID":"S1322","APPLICATION_DATE":"2020-06-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-24","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application to replace a smoke detector required by OBC 3.2.4.12. (5)(a) with a heat detector.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":12,"PERMIT_NUM":"20 154448 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"502","STREET_NAME":"ADELAIDE","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"7930863","WARD_GRID":"S1029","APPLICATION_DATE":"2020-06-10","ISSUED_DATE":null,"COMPLETED_DATE":"2021-11-09","STATUS":"Approved","DESCRIPTION":"AS-LEVEL 2 DEAD END PUBLIC CORRIDORProposal to construct a new mixed use building with 116 residential units, retail at grade, rooftop amenity terrace and 4 levels of underground parking.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":13,"PERMIT_NUM":"20 154452 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"502","STREET_NAME":"ADELAIDE","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"7930863","WARD_GRID":"S1029","APPLICATION_DATE":"2020-06-10","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-18","STATUS":"Approved","DESCRIPTION":"AS-STANDPIPE HOSE CONNECTION WITHIN EXIT STAIRSProposal to construct a new mixed use building with 116 residential units, retail at grade, rooftop amenity terrace and 4 levels of underground parking.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":14,"PERMIT_NUM":"20 154253 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"6351","STREET_NAME":"STEELES","STREET_TYPE":"AVE","STREET_DIRECTION":"E","POSTAL":"M1X","GEO_ID":"4950696","WARD_GRID":"E2325","APPLICATION_DATE":"2020-06-09","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-04","STATUS":"Approved","DESCRIPTION":"ALTERNATIVE SOLUTION FOR EXITING INCLUDING RACK AND SHELF STORAGE","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":15,"PERMIT_NUM":"20 148498 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"81","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30071250","WARD_GRID":"S1037","APPLICATION_DATE":"2020-05-25","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-15","STATUS":"Approved","DESCRIPTION":"To permit Level 48 to serve as the cross-over floor for the office tower, and to permit mechanical Level 50 to serve as a cross-over floor for the mechanical levels above in lieu of providing a cross-over floor on Level 49.  ( In connection with Building Permit Application 17-137140)","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":16,"PERMIT_NUM":"20 154444 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"57","STREET_NAME":"SPADINA","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"10222988","WARD_GRID":"S1033","APPLICATION_DATE":"2020-06-10","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-23","STATUS":"Cancelled","DESCRIPTION":"The 57 Spadina project consists of a 36 storey residential tower and a 4 level basement.   The building will be designed in accordance with OBC Article 3.2.2.42 (Group C, Any Height, Any Area, Sprinklered).The building will be provided with electrically supervised automatic sprinkler protection throughout as per OBC Article 3.2.2.42.  Furthermore, a fire alarm system connected to a central station will be provided throughout the building.The alternative measure is based on a combination of provisions of the 2012 Ontario Building Code (OBC), the 2010 National Building Code of Canada (NBC), and NFPA 14 ¿Installation of Standpipe and Hose Systems¿ 2013 Edition.No hose cabinets will be provided, and only 65mm dia. Hose connections will be provided in all storeys.  Details of the proposed standpipe system design and alternative solution include:standpipe risers and hose connections located in exit stair shafts based on OBC 3.2.9.2.(9) and 6.1.2.2. in NFPA 14conformance with OBC 3.2.9.7.(1) and (2): flow at the two hydraulically most remote hose connections of not less than 1890L/min for 30 minutes at a pressure of not less than 450kPa, and not less than 945L/min from each of the two outlets simultaneously, with the water supply supplied through the Fire Department Connection.33m of hose coverage based on 30m hose and 3m of discharge based on OBC 3.2.9.4.(2) and (5)fire extinguisher provided as required in Part 6 of the 2007 Ontario Fire Codetwo (2) 30m lengths of 38mm dia. Fire hose with nozzle will be kept at the CACF Room for possible discretionary use by fire department personnel.         ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":17,"PERMIT_NUM":"20 155693 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"156","STREET_NAME":"FRONT","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5J","GEO_ID":"7929381","WARD_GRID":"S1033","APPLICATION_DATE":"2020-06-12","ISSUED_DATE":null,"COMPLETED_DATE":"2021-04-14","STATUS":"Approved","DESCRIPTION":"Proposal for alternative solution for the Omission of Fire Hose Cabinets related to 18 236859 NB - 160 Front st W","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":18,"PERMIT_NUM":"20 151838 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"440","STREET_NAME":"FRONT","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"13323714","WARD_GRID":"S1032","APPLICATION_DATE":"2020-06-03","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-18","STATUS":"Approved","DESCRIPTION":"Alternative Solution - For interconnected floor space.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":19,"PERMIT_NUM":"20 138114 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1001","STREET_NAME":"QUEEN","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M6J","GEO_ID":"20232082","WARD_GRID":"S1027","APPLICATION_DATE":"2020-04-24","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-05","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution to Ontario Building Code requirements applicable to plumbing fixtures accessories considered to be a ligature risk with barrier-free washrooms accessible to patients within high security areas in the CAMH (Centre for Addiction and Mental Health - D1 Building addition","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":20,"PERMIT_NUM":"20 136724 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"39","STREET_NAME":"ROEHAMPTON","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4P","GEO_ID":"7664599","WARD_GRID":"S1221","APPLICATION_DATE":"2020-04-22","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-22","STATUS":"Cancelled","DESCRIPTION":"The proposed Alternative Solution contains a rationale to waive requirements for fire separation of exits and to support the design of the dedicated exterior path located directly adjacent to the parking garage drive aisle and along the east exterior façade of the proposed 39-41 Roehampton condominium building located in Toronto, Ontario. The dedicated exterior exit path will be located directly under the floor assembly of the Second Floor of the building which contains a residential occupancy. The exit path will be provided with a clear width of 1100 mm and clearly demarcated so that no obstructions or vehicles will be permitted to park or obstruct the path at any given time. The proposed Alternative Solution is based on the Objectives and Functional Statements attributed to the applicable Acceptable Solutions of the objective based 2012 Ontario Building Code.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":21,"PERMIT_NUM":"20 138371 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"181","STREET_NAME":"BEDFORD","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30086019","WARD_GRID":"S1127","APPLICATION_DATE":"2020-04-24","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-15","STATUS":"Approved","DESCRIPTION":"This is to replace the approved AS under permit 18-116848 ALT 00 AS.  It  is updated to address constructing the Measure N vestibule walls facing the parking garage on Level P2 of sprinkler-protected glazed wall assemblies conforming to OBC Article 3.1.8.18 based on aesthetic  requirements.  This has been prepared to address the smoke control for connected building requirements for  Block D and the below-grade parking garage of the proposed condominium/townhouse development.  This is specific to Phase 3, which includes the construction of two townhouse blocks (divided by firewalls into six OBC-defined buildings) above an underground parking garage, with direct connections provided between the garage and each dwelling unit within the townhouse blocks.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":22,"PERMIT_NUM":"20 134246 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"248","STREET_NAME":"HIGH PARK","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M6P","GEO_ID":"8005205","WARD_GRID":"S0428","APPLICATION_DATE":"2020-04-16","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-02","STATUS":"Refused","DESCRIPTION":"Alternative Solution Application to provide a water curtain system comprised of closely spaced sprinklers on the interior side of the main entrance lobby exterior doors (facing the central courtyard) to offset the exit exposure condition caused by the proximity of the glazed sliding door assembly in the entrance vestibule.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":23,"PERMIT_NUM":"20 134261 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"248","STREET_NAME":"HIGH PARK","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M6P","GEO_ID":"8005205","WARD_GRID":"S0428","APPLICATION_DATE":"2020-04-16","ISSUED_DATE":null,"COMPLETED_DATE":"2021-07-08","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application is specific to units 103 ,104 and 402 to implement measures to offset the approximately 1.7m excess floor height above the maximum height threshold of 6m in order to apply the permission to waive fire separation construction for the floor assemblies entirely within the above noted suites. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":24,"PERMIT_NUM":"20 142890 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1221","STREET_NAME":"KING","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M6K","GEO_ID":"828426","WARD_GRID":"S0437","APPLICATION_DATE":"2020-05-06","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-11","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application to provide a standpipe system, 65 mm hose connections will be located within the exit stairs, and on the floor areas where the required 33 m hose coverage cannot be achieved with the hose connections in the stairs. Hose stations will not be provided in the floor areas of the building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":25,"PERMIT_NUM":"20 135623 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1095","STREET_NAME":"LESLIE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"20230223","WARD_GRID":"N1626","APPLICATION_DATE":"2020-04-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-10","STATUS":"Approved","DESCRIPTION":"Proposed alternitive solution to use TP304 SCH 10 stainless steel (SS) pipe as an alternitive to type L copper for domestic water main riser for added safety of higher working pressuse rating of SS Pipe (Listed @ 1000 PSIG) compared to type L Copper (Listed @ 504 PSIG). SS Pipe proposed to be installed using victaulic rigid coupling sytle 89 or welded joint for joint fittings. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":26,"PERMIT_NUM":"20 142519 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"YORKVILLE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4W","GEO_ID":"8677241","WARD_GRID":"S1128","APPLICATION_DATE":"2020-05-05","ISSUED_DATE":null,"COMPLETED_DATE":"2021-01-07","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application to address the residential and office dead-end public corridor condition exceeding the maximum permitted 6.0 m and 9.0 m lengths, as required by the OBC.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":27,"PERMIT_NUM":"20 143427 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"181","STREET_NAME":"BEDFORD","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30086019","WARD_GRID":"S1127","APPLICATION_DATE":"2020-05-07","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-08","STATUS":"Approved","DESCRIPTION":"Alternative Solution proposal for Interconnected Floor Space (P2 to Ground) for the AYC Condominium regarding  #17 220118 NB.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":28,"PERMIT_NUM":"20 141007 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"CENTRE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"7792169","WARD_GRID":"S1025","APPLICATION_DATE":"2020-04-30","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-04","STATUS":"Approved","DESCRIPTION":"Proposed Alternative Solution is to permit electromagnetic locking devices installed on secondary egress doors from medium size courtrooms at the New Toronto Courthouse to release on second stage fire alarm activation. When court is in session within a medium size courtroom, the electromagnetic locking devices on secondary egress doors will be released manually by courtroom security staff.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":29,"PERMIT_NUM":"20 158046 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"117","STREET_NAME":"BROADWAY","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4P","GEO_ID":"776690","WARD_GRID":"S1221","APPLICATION_DATE":"2020-06-19","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-08","STATUS":"Approved","DESCRIPTION":"Proposed Standpipe Alternate Solution for 36 Storey North Tower consisting of 504 Units and 33 Storey South Tower consisting of 420 with 2 Levels of U/G Parking","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":30,"PERMIT_NUM":"20 158183 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"320","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5H","GEO_ID":"10222920","WARD_GRID":"S1034","APPLICATION_DATE":"2020-06-19","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-10","STATUS":"Cancelled","DESCRIPTION":"Installation of 3M fire barrier duct wrap 615 for protection of existing standpipe riser in the southwest corner of floor area, in lieu of re-locating riser to exit stair or service shaft.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":31,"PERMIT_NUM":"20 151576 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"165","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115227","WARD_GRID":"W0533","APPLICATION_DATE":"2020-06-02","ISSUED_DATE":null,"COMPLETED_DATE":"2021-10-28","STATUS":"Cancelled","DESCRIPTION":"AS-FIRE ALARM SIGNAL STAGINGConstruct a 6 storey midrise building with 88 units on top of and underground garage. Building R","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":32,"PERMIT_NUM":"20 144415 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"81","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30071250","WARD_GRID":"S1037","APPLICATION_DATE":"2020-05-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-31","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution Application for Grease interceptors (proposal to enclose the installed grease interceptors in a  2 h fire separated enclosure that will contain no other occupancy or equipment).","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":33,"PERMIT_NUM":"20 154805 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"40","STREET_NAME":"TEMPERANCE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"8676916","WARD_GRID":"S1333","APPLICATION_DATE":"2020-06-10","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-10","STATUS":"Approved","DESCRIPTION":"Grease interceptor tank.This AS application is under the general building permit # 18 264 306 BLD 00 BA.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":34,"PERMIT_NUM":"20 154476 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"99","STREET_NAME":"BLUE JAYS","STREET_TYPE":"WAY","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"6195885","WARD_GRID":"S1033","APPLICATION_DATE":"2020-06-10","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-07","STATUS":"Cancelled","DESCRIPTION":"Combustible composite metal panel system, installed in limited areas on the exterior face of the new 55 mercer condo  building which exceeds 6 storeys, will provide the level of performance required by 3.1.5.5 (1) and (2) of the 2012 OBC, Ontario Regulation 332/12, amendment 88/19, effective January 1, 2020. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":35,"PERMIT_NUM":"20 148672 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"440","STREET_NAME":"FRONT","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"13323714","WARD_GRID":"S1032","APPLICATION_DATE":"2020-05-26","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-08","STATUS":"Approved","DESCRIPTION":"Alternative Solution -The Well will be a multiple tower mixed-use development consisting of 7 towers (Blocks A through G) with common basement parking levels, which is classified as a single building. The building is classified as a high building, with towers ranging from 16 ¿ 38 storeys in height. The project includes 3 levels of retail space on the ground level (1st storey) and the next full storeys above (Level 02) and below (Lower Ground Level). This alternative solution addresses the proposed application of OBC Sentence 3.2.8.2.(6) permitting interconnected floor spaces between the 1st storey and only the storey next above or below, but not both, to the Well with proposed openings to storeys both above and below the 1st storey. The alternative solution proposes the provision of 1st storey vertical fire separations having fire-resistance ratings equivalent to floor assemblies between portions of the storey having openings to the storey above and openings to the storey below. It is not intended to apply requirements of OBC 3.2.8.3 ¿ 3.2.8.11. This proposal is an update of an alternative solution that was approved August 2, 2019. The update reflects the inclusion of the Block G entrance lobby as an interconnected floor space with Level 2. The approach is similar to that in the previously approved alternative solution addressing the interconnection of the ground floor and Level 2 in Block F with an intervening intermediate retail floor level separated from the interconnected floor space.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":36,"PERMIT_NUM":"20 145082 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"81","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30071250","WARD_GRID":"S1037","APPLICATION_DATE":"2020-05-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-02","STATUS":"Approved","DESCRIPTION":"Alternative Solution - proposal to enclose the installed grease interceptors in a two hour fire separated enclosure that will contain no other occupancy or equipment","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":37,"PERMIT_NUM":"20 144841 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"170","STREET_NAME":"EMMETT","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30122902","WARD_GRID":"W0531","APPLICATION_DATE":"2020-05-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-26","STATUS":"Approved","DESCRIPTION":"Alternative solution:West park health care centre will be provided with a standpipe system, with 65 mm hose connections located within the exit stairs, and on the floor areas where required 33 m hose coverage cannot be achieved with hose connections in the stairs.hose stations will not be provided in the floor areas.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":38,"PERMIT_NUM":"20 144852 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"170","STREET_NAME":"EMMETT","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30122902","WARD_GRID":"W0531","APPLICATION_DATE":"2020-05-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-14","STATUS":"Approved","DESCRIPTION":"Alternative solution:It is proposed to provide a non-slip shower chair with full back support instead of a fixed or non-spring-loaded hinged seat as required by OBC Div. B 3.8.3.13(2)(e).","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":39,"PERMIT_NUM":"20 144856 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"82","STREET_NAME":"BUTTONWOOD","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M6M","GEO_ID":"54248","WARD_GRID":"W0531","APPLICATION_DATE":"2020-05-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-15","STATUS":"Approved","DESCRIPTION":"it is proposed to provide stainless steel piping for potable water services in lieu of copper piping as Alternative solution: required by obc 7.2.7.1.(1). please refer to vortex fire report \"vft17156r04 wphc stainless steel piping alt solution 07may2020\".","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":40,"PERMIT_NUM":"20 144857 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"170","STREET_NAME":"EMMETT","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30122902","WARD_GRID":"W0531","APPLICATION_DATE":"2020-05-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-22","STATUS":"Approved","DESCRIPTION":"Alternative solution:it is proposed to not provide back support for water closets in barrier free washrooms in the abibs department (department 12) and tb section 35 room of the proposed building. please refer to report by vortex fire \"vft17156r05 wphc abibs dept. and tb alt. solution 05may2020\" for details of proposal.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":41,"PERMIT_NUM":"20 151368 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"20","STREET_NAME":"EDWARD","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5G","GEO_ID":"7762734","WARD_GRID":"S1145","APPLICATION_DATE":"2020-06-02","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-20","STATUS":"Approved","DESCRIPTION":"To allow for an alternative solution to stand pipe system as described in the attached Evaluation of Alternative Solutions. (reference to 18-120574 BLD) ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":42,"PERMIT_NUM":"20 142981 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"ORDNANCE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M6K","GEO_ID":"3121362","WARD_GRID":"S1028","APPLICATION_DATE":"2020-05-06","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-31","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution Application to use grade TP304 Sch 40 stainless steel (SS) pipe as an alternative to Type L Copper for domestic water main riser.  SS pipe proposed to be installed using victalic rigid coupling style 89.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":43,"PERMIT_NUM":"20 145303 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"40","STREET_NAME":"TEMPERANCE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"8676916","WARD_GRID":"S1333","APPLICATION_DATE":"2020-05-14","ISSUED_DATE":null,"COMPLETED_DATE":"2020-11-03","STATUS":"Approved","DESCRIPTION":"Proposed alternative solution for a closely spaced sprinkler and smoke detector in with a noncombustible draft stop header above unrated doors in a max 20 m. sq. vertical opening in the 2 h fire separation on the second floor will achieve the level of performance required by the applicable acceptable solution with respect to OBC 3.2.8.2.(5). ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":44,"PERMIT_NUM":"20 142286 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"4841-4881","STREET_NAME":"YONGE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M2N","GEO_ID":"14190453","WARD_GRID":"N1826","APPLICATION_DATE":"2020-05-05","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-13","STATUS":"Approved","DESCRIPTION":"It is proposed to protect the gas lines which supply the emergency generator on the tower roof of the yonge sheppard residential tower with a fire weap product designated 3m fire barrier duct weap 615 in order to provide the required 2 hour fire-resistance rating in lieu of a traditional gypsum board steel stud shaft wall enclosure.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":45,"PERMIT_NUM":"11 298455 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"111","STREET_NAME":"ST CLAIR","STREET_TYPE":"AVE","STREET_DIRECTION":"W","POSTAL":"M4V","GEO_ID":"871421","WARD_GRID":"S1238","APPLICATION_DATE":"2011-10-25","ISSUED_DATE":null,"COMPLETED_DATE":"2019-01-10","STATUS":"Approved","DESCRIPTION":"Proposal for alternative solution for the installation of standpipe (2 risers) for construction in existing mixed-use office building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":46,"PERMIT_NUM":"19 260312 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1580","STREET_NAME":"AVENUE","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"M5M","GEO_ID":"484878","WARD_GRID":"N0824","APPLICATION_DATE":"2019-12-12","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-06","STATUS":"Approved","DESCRIPTION":"Avenue and Park will be provided with a standpipe system 65 mm hose connections will be located within the exit stairs, and on the floor areas where the required 33 m hose coverage cannot be achieved with the hose connections in the stairs. Hose stations will not be provided in the floor areas of the building","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":47,"PERMIT_NUM":"19 224725 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"191","STREET_NAME":"EVANS","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M8Z","GEO_ID":"10998870","WARD_GRID":"W0332","APPLICATION_DATE":"2019-09-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-01-14","STATUS":"Approved","DESCRIPTION":"Proposed Through use of a time - based egress analysis, it is demonstrated that the level of life safety provided in the cold storage areas with the panel system is comparable to that provided by the referenced acceptable solutions in the 2012 Ontario Building Code.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":48,"PERMIT_NUM":"19 228200 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"403","STREET_NAME":"CHURCH","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30086351","WARD_GRID":"S1326","APPLICATION_DATE":"2019-09-27","ISSUED_DATE":null,"COMPLETED_DATE":"2020-03-23","STATUS":"Approved","DESCRIPTION":"This alternative solution proposes elimination of a man door within an overhead parking garage door and utilizing the exterior overhead parking garage door as a means of egress form the Ground Floor level.The overhead door will be connected to emergency power, will be provided with a local pull station and emergency egress button, and will be monitored via CCTV at all times by building security / concierge.For the description of the alternative soloution see the application form","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":49,"PERMIT_NUM":"19 222024 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1001","STREET_NAME":"SHEPPARD","STREET_TYPE":"AVE","STREET_DIRECTION":"E","POSTAL":"M2K","GEO_ID":"30010324","WARD_GRID":"N1729","APPLICATION_DATE":"2019-09-16","ISSUED_DATE":null,"COMPLETED_DATE":"2019-11-08","STATUS":"Approved","DESCRIPTION":"AS-PIPING AND VICTAULIC STAINLESS STEEL FITTINGSPlumbing  - Underground parking garage for the development of two towers (33 adn 36 stories) and two blocks of stacked townhouses(4 stories) and a shared podium","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":50,"PERMIT_NUM":"19 241855 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"350","STREET_NAME":"QUEENS QUAY","STREET_TYPE":" ","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"10223461","WARD_GRID":"S1036","APPLICATION_DATE":"2019-10-28","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-25","STATUS":"Approved","DESCRIPTION":"It is proposed to provide 65 mm standpipe system hose valve connections in general conformance with the 2015 National Building Code (NBC) and the 2013 Edition of NFPA 14, `Standard for Installation of Standpipe and Hose System\" (as referenced by the NBC) in this fully sprinklered building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":51,"PERMIT_NUM":"19 238989 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"55","STREET_NAME":"LAKE SHORE","STREET_TYPE":"BLVD","STREET_DIRECTION":"E","POSTAL":"M5E","GEO_ID":"829580","WARD_GRID":"S1038","APPLICATION_DATE":"2019-10-21","ISSUED_DATE":null,"COMPLETED_DATE":"2021-05-12","STATUS":"Approved","DESCRIPTION":"Proposal to permit the use of 65 mm standpipe hose valves in exit stairs in lieu of fire hose cabinets containing 65 mm and 38mm hose valves with 38 mm fire hoses within floor areas.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":52,"PERMIT_NUM":"19 248170 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"40","STREET_NAME":"WIDMER","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"7930420","WARD_GRID":"S1030","APPLICATION_DATE":"2019-11-12","ISSUED_DATE":null,"COMPLETED_DATE":"2021-04-15","STATUS":"Approved","DESCRIPTION":"The purpose of this alternative solution is to address the OBC requirement to install fire hose cabinets within for areas that are located not more than 5m from every required exit serving this project. On an alterative solution basis, it is proposed to omit the installation of hose cabinets within floor areas. Rather, 65mm hose connections will be installed within the exit stair shafts as required for this project in accordance with the 2015 National building Code of Canada (NBC) Sentence 3.2.5.10.(1) and NFPA 14-2010 \"Installation of Standpipe and Hose Systems\".","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":53,"PERMIT_NUM":"19 251348 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"39","STREET_NAME":"EAST LIBERTY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"14600165","WARD_GRID":"S1027","APPLICATION_DATE":"2019-11-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-29","STATUS":"Approved","DESCRIPTION":"As requested by 39 East Liberty GP Inc., as a General Partner for 39 East Liberty Residences LP, Matteo Gilfillan & Associates Inc. (MGA) has prepared this correspondence to summarize the proposed Alternative Solution regarding the hydraulic load contribution of emergency drains proposed in the laundry (washer / dryer) closets of the dwelling units for the residential building to be located at 39 East Liberty Street, in Toronto, Ontario.This correspondence has been prepared with respect to Sentence 7.4.9.3.(1) of the 2012 Ontario Building Code (OBC, O.Reg. 332/12 as amended to O.Reg. 88/19) as well as the Alternative Solution Proposal requirements in Division C, Article 2.1.1.1 of the 2012 Ontario Building Code.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":54,"PERMIT_NUM":"19 209420 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"81","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30071250","WARD_GRID":"S1037","APPLICATION_DATE":"2019-08-21","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-18","STATUS":"Approved","DESCRIPTION":"Level 41 to Level 44 of the building at 81 Bay Street is a single suite owned by Microsoft. The exits serving each floor area has capacity for 324 persons. It is proposed to increase the occupant load on level 43 to 373. Please refer to attached report by Vortex Fire Consulting Inc. \"VFT19034R01 81 Bay Street MSFT Lv 41-44 Alt Sol 13Aug2019\".","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":55,"PERMIT_NUM":"20 110453 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"91","STREET_NAME":"BROADWAY","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4P","GEO_ID":"7632835","WARD_GRID":"S1221","APPLICATION_DATE":"2020-01-30","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-28","STATUS":"Approved","DESCRIPTION":"To address the design of having 2 sides of the residential amenity pool be surrounded by a minimum 1800 mm wide deck(with thre remaining sides having a reduced width) for the public pool serving the mix-use/residential building","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":56,"PERMIT_NUM":"19 239735 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"175","STREET_NAME":"ELIZABETH","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5G","GEO_ID":"10906827","WARD_GRID":"S1145","APPLICATION_DATE":"2019-10-22","ISSUED_DATE":null,"COMPLETED_DATE":"2019-12-10","STATUS":"Approved","DESCRIPTION":"Proposal for an alternate solution related for Standpipe system in the exit stair well., no FHC  cabinet on the floors","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":57,"PERMIT_NUM":"19 253337 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"93","STREET_NAME":"BERKELEY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5A","GEO_ID":"771192","WARD_GRID":"S1335","APPLICATION_DATE":"2019-11-25","ISSUED_DATE":null,"COMPLETED_DATE":"2020-03-03","STATUS":"Approved","DESCRIPTION":"Alternative Sulutions -Propose to protect selected horizontal portion of standpipe riser with a fire-rated 3M warp assembly having 1 hr or 2 hr fire-resistance rating, where they are not located within a stair shaft or fire rated service space.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":58,"PERMIT_NUM":"19 227491 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"185","STREET_NAME":"QUEENS QUAY","STREET_TYPE":" ","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"30017888","WARD_GRID":"S1038","APPLICATION_DATE":"2019-09-26","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-24","STATUS":"Approved","DESCRIPTION":"Alternative Solution for use of mass timber (CLT and Glulam) for 10 Storey  educational facility  building at George Brown College Waterfront Campus - known as The Arbour.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":59,"PERMIT_NUM":"19 263943 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"YORKVILLE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4W","GEO_ID":"8677241","WARD_GRID":"S1128","APPLICATION_DATE":"2019-12-20","ISSUED_DATE":null,"COMPLETED_DATE":"2021-03-10","STATUS":"Refused","DESCRIPTION":"Proposal to utilize a transfer wall designed in accordance for barrier-free access to 3rd floor public pool.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":60,"PERMIT_NUM":"19 263946 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"YORKVILLE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4W","GEO_ID":"8677241","WARD_GRID":"S1128","APPLICATION_DATE":"2019-12-20","ISSUED_DATE":null,"COMPLETED_DATE":"2021-01-11","STATUS":"Approved","DESCRIPTION":"Proposal to have only portion of 2 sides of the residential amenity pool surrounded by a minimum 1800 mm wide deck and only 2 sides of the spa surrounded by an 1800 mm wide deck.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":61,"PERMIT_NUM":"19 263952 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"YORKVILLE","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M4W","GEO_ID":"8677241","WARD_GRID":"S1128","APPLICATION_DATE":"2019-12-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-28","STATUS":"Approved","DESCRIPTION":"Proposal for 65 mm diameter standpipe hose connections within the exit stairs in lieu of traditional fire hose cabinets containing 38 mm and 65 mm diameter hose connections as well as 30 m of fire hose.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":62,"PERMIT_NUM":"19 206277 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"385","STREET_NAME":"CHURCH","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5B","GEO_ID":"783047","WARD_GRID":"S1328","APPLICATION_DATE":"2019-08-15","ISSUED_DATE":null,"COMPLETED_DATE":"2019-09-23","STATUS":"Approved","DESCRIPTION":"Propose that a standpipe riser located outside of exit stair and service shaft and protected using Cl4FIRE Blue Lable and Red Label producats (tested and rated in accordance with ULC requirements for fire resistant ducts) is permitted on the basis tht the proposed a fire-rated wrap assembly provides a 1 h or 2 H fire-resistance rating.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":63,"PERMIT_NUM":"20 126621 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"620","STREET_NAME":"DUNDAS","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"20362101","WARD_GRID":"S1330","APPLICATION_DATE":"2020-03-16","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-28","STATUS":"Approved","DESCRIPTION":"Alternative solution for standpipes - associated with File 19 153651 BLD","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":64,"PERMIT_NUM":"19 259804 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1","STREET_NAME":"ADRA VILLAWAY","STREET_TYPE":" ","STREET_DIRECTION":" ","POSTAL":"M2J","GEO_ID":"14070849","WARD_GRID":"N1726","APPLICATION_DATE":"2019-12-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-04","STATUS":"Approved","DESCRIPTION":"This submission summarizes the Alternative Solution Proposal for the design of the indoor pool deck on Level 00 (Ground Floor) and the outdoor pool deck on Level 05 of the Scala Block D project to be constructed in Toronto, Ontario. The overall project consists of an 17-storey residential building with amenity uses located on the Ground Floor, Level 05 and Level 12. The building is situated over three levels of below-grade parking. This Alternative Solution Proposal details the intended compensating measures to be applied due to the omission of the pool deck located on the East side of the indoor pool and the North side of the outdoor pool","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":65,"PERMIT_NUM":"19 259809 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1","STREET_NAME":"ADRA VILLAWAY","STREET_TYPE":" ","STREET_DIRECTION":" ","POSTAL":"M2J","GEO_ID":"14070849","WARD_GRID":"N1726","APPLICATION_DATE":"2019-12-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-01-23","STATUS":"Approved","DESCRIPTION":"For all floor levels, it is proposed to design a standpipe system in a manner that standpipe risers provided with hose connections will be located in the existing stair enclosures in lieu of providing fire hose cabinets in the floor areas. Additional fire hose connections will be provided to provide 33m coverage. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":66,"PERMIT_NUM":"19 248995 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"2189","STREET_NAME":"GERRARD","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"M4E","GEO_ID":"7640836","WARD_GRID":"S1935","APPLICATION_DATE":"2019-11-14","ISSUED_DATE":null,"COMPLETED_DATE":"2019-12-02","STATUS":"Approved","DESCRIPTION":"The existing building is undergoing a change of occupancy and in accordance with Part 11, the first floor is required to have a  sprinkle system. This Alternative Solution will address the requirement for sprinklers.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":67,"PERMIT_NUM":"19 260017 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1808","STREET_NAME":"ST CLAIR","STREET_TYPE":"AVE","STREET_DIRECTION":"W","POSTAL":"   ","GEO_ID":"30117485","WARD_GRID":"S0923","APPLICATION_DATE":"2019-12-11","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-28","STATUS":"Approved","DESCRIPTION":"To permit the use of 65mm standpipe hose valves in exit stairs in lieu of fire hose cabinets containing 65mm and 38mm hose valves with 38mm fire hoses within the floors having Group C (residential), Group D (office), Group E (retail) and Group F, Division 3 major occupancies","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":68,"PERMIT_NUM":"19 251447 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"350","STREET_NAME":"QUEENS QUAY","STREET_TYPE":" ","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"10223461","WARD_GRID":"S1036","APPLICATION_DATE":"2019-11-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-22","STATUS":"Approved","DESCRIPTION":"Alternative solution to permit the application of MMAH Supplementary Standard SB-4, \"Measures for Fire Safety in High Buildings\" Measure A requirements to the 370 Queens Quay West tower and separate 370 Queens Quay West from the remainder of the development by the provision of Measure N vestibules between the new 370 Queens Quay West (QQW) and the existing 350, 390, and 396 QQW towers.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":69,"PERMIT_NUM":"19 201930 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"2201","STREET_NAME":"KINGSTON","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"M1N","GEO_ID":"2893892","WARD_GRID":"E2035","APPLICATION_DATE":"2019-08-07","ISSUED_DATE":null,"COMPLETED_DATE":"2021-01-18","STATUS":"Approved","DESCRIPTION":"Proposal to provide 65 mm hose connections in lieu of the hose stations(38mm and 65 mm hose valves, 38 mm hose and nozzle) required by the 2012 Ontario building code. The standpipe and the hose connections will be located within exit stair enclosures. Note: Scissor stairs are not provided within the building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":70,"PERMIT_NUM":"19 261402 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"875","STREET_NAME":"EGLINTON","STREET_TYPE":"AVE","STREET_DIRECTION":"W","POSTAL":"M6C","GEO_ID":"8594597","WARD_GRID":"S1224","APPLICATION_DATE":"2019-12-14","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-24","STATUS":"Approved","DESCRIPTION":"875 Eglinton Avenue West will be provided with a standpipe system. 65 mm hose connections will be located within the exit stairs, and on the floor areas where the required 33 m hose coverage cannot be achieved with the hose connections in the stairs. Hose stations will not be provided in the floor areas of the building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":71,"PERMIT_NUM":"19 261944 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1","STREET_NAME":"QUEEN","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"M5C","GEO_ID":"11272991","WARD_GRID":"S1334","APPLICATION_DATE":"2019-12-16","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-30","STATUS":"Approved","DESCRIPTION":"Alternative Solution for the proposed use of turnstiles( SlimLane Portal 950) on the ground floor with a man door with mag lock adjust to this gate","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":72,"PERMIT_NUM":"19 199108 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"30","STREET_NAME":"TIPPETT","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30010354","WARD_GRID":"N0633","APPLICATION_DATE":"2019-08-01","ISSUED_DATE":null,"COMPLETED_DATE":"2021-02-16","STATUS":"Approved","DESCRIPTION":"It is proposed to provide 65mm standpipe system hose valve connections in general conformance with the 2015 National Building Code (NBC) AND THE 2013 eDITION OF nfpa 14, 'Stanard for installation of stadpipe and Hose System ( as referenced by the NBC) in this fully sprinklered building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":73,"PERMIT_NUM":"19 199114 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"30","STREET_NAME":"TIPPETT","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30010354","WARD_GRID":"N0633","APPLICATION_DATE":"2019-08-01","ISSUED_DATE":null,"COMPLETED_DATE":"2021-02-16","STATUS":"Approved","DESCRIPTION":"it is proposed to provide 65mm standpipe system hose valve connections in general conformance with the 2015 National Building Code (NBC) AND THE 2013 eDITION OF nfpa 14, 'Stanard for installation of stadpipe and Hose System ( as referenced by the NBC) in this fully sprinklered building.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":74,"PERMIT_NUM":"19 216449 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"41","STREET_NAME":"DOVERCOURT","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"M6J","GEO_ID":"794043","WARD_GRID":"S1027","APPLICATION_DATE":"2019-09-05","ISSUED_DATE":null,"COMPLETED_DATE":"2019-09-05","STATUS":"Approved","DESCRIPTION":"PROPOSING A STANDPIPE SYSTEM IN WHICH STANDPIPE RISERS WITH 65 MM HOSE CONNECTIONS WILL BE LOCATED IN THE EXIT STAIR ENCLOSURES. THE 65 MM HOSE CONNECTIONS WILL BE PROVIDED IN LIEU OF HOSESTATIONS.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":75,"PERMIT_NUM":"20 116934 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"10","STREET_NAME":"EVA","STREET_TYPE":"RD","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30031438","WARD_GRID":"W0233","APPLICATION_DATE":"2020-02-19","ISSUED_DATE":null,"COMPLETED_DATE":"2020-11-25","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application to provide 65 mm standpipe system hose valve connections in exit stairs in lieu of 38mm and 65mm hose stations.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":76,"PERMIT_NUM":"19 260981 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1313","STREET_NAME":"LAKE SHORE","STREET_TYPE":"BLVD","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"7650409","WARD_GRID":"S1442","APPLICATION_DATE":"2019-12-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-05-04","STATUS":"Approved","DESCRIPTION":"Alternative solution for timed egress analysis for travel distance exceeding 30m on all floor levels to 3rd floor.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":77,"PERMIT_NUM":"20 112781 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"57","STREET_NAME":"SPADINA","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"10222988","WARD_GRID":"S1033","APPLICATION_DATE":"2020-02-05","ISSUED_DATE":null,"COMPLETED_DATE":"2021-04-14","STATUS":"Approved","DESCRIPTION":"Alternative Solution to use grade TP 304 SCH 10 (SS) pipe as alternative to Type L copper for domestic water main riser for added safety of higher working pressure rating or (SS) pipe (listed @ 1000 PSIG) compared to type L copper (Listed @ 504 PSIG), (SS) pipe proposed to be installed using victaulic rigid coupling style 89 or welded joint for joint fitting.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":78,"PERMIT_NUM":"19 199711 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"2439","STREET_NAME":"EGLINTON","STREET_TYPE":"AVE","STREET_DIRECTION":"E","POSTAL":"M1K","GEO_ID":"4257460","WARD_GRID":"E2023","APPLICATION_DATE":"2019-08-02","ISSUED_DATE":null,"COMPLETED_DATE":"2019-08-22","STATUS":"Approved","DESCRIPTION":"Elevator shaft construction requirements","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":79,"PERMIT_NUM":"20 116522 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"2161","STREET_NAME":"YONGE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M4S","GEO_ID":"11272588","WARD_GRID":"S1228","APPLICATION_DATE":"2020-02-18","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-08","STATUS":"Approved","DESCRIPTION":"Alternative solution proposal reviews the requirements of locating the standpipe riser within the exit stair shaft and deleting the fire hose cabinets.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":80,"PERMIT_NUM":"19 248397 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"0","STREET_NAME":"FREDERICK TISDALE","STREET_TYPE":"CRCL","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":null,"WARD_GRID":"N0628","APPLICATION_DATE":"2019-11-13","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-08","STATUS":"Approved","DESCRIPTION":"Revision to folder #19-140614 ALT 00 ASAlternative Solution to the  Egress from the third and fourth storeys within the dwelling units with respect to OBC 3.3.4.4.(4). Balconies with 1 h fire resistance rating will be provided on levels three and four. An enclosed exit stair will be provided with a door on both levels. To reduce smoke spread sprinklers will be provided around the opening between level two and three, and the doors around the landing on levels three and four will be provided with self closing devices.The compensatory measures are intended to achieve compliance with the OBC by satisfying the functional andobjective statements associated with OBC 3.3.4.4.(4).o Block 08 - 18 - 229611, Block 09 - 18 -229956, Block 10 - 18 -229969, Block 11 - 232602Block 12 - 18 - 233523, Blcok 13 - 18 - 235863, Block 14 - 18 -235870, Block 15 18 -235877, Block 16 - 18 - 235885, Block 17 - 18 - 235897, Block 18 - 18 - 232663, Block 19 - 18 - 232685, Block 20 - 18 - 232698, Block 21- 18 - 232737.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":81,"PERMIT_NUM":"20 126569 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1555","STREET_NAME":"FINCH","STREET_TYPE":"AVE","STREET_DIRECTION":"E","POSTAL":"M2J","GEO_ID":"10906835","WARD_GRID":"N1727","APPLICATION_DATE":"2020-03-16","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-25","STATUS":"Cancelled","DESCRIPTION":"It is proposed that on P1 and P2 parking levels, the existing fire hose cabinets and hoses be removed, fire extinguishers be relocated on the opposite side of the columns in fire extinguisher cabinets and the existing 65 mm standpipe system hose valve connections stay in place and be protected by appropriate guards/cabinets.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":82,"PERMIT_NUM":"19 239975 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"155","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115226","WARD_GRID":"W0533","APPLICATION_DATE":"2019-10-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-28","STATUS":"Approved","DESCRIPTION":"BLOCKS 3 & 4 - Bldg K - There are 2 (two) issues to be addressed in this Alternative Solution for the townhouses.  Sentence 9.9.9.1.(1) requires the exit door for the townhouse units to be not more than 1.5m above adjacent ground level and not necessary to travel down more than 1 (one) storey to reach the level served by this exit door.  Secondly, Sentence 9.9.4.4.(1) requires openings in the exterior wall of adjacent fire compartments within 3m horizontally and 10m below or 5m above the exterior exit stair to be protected.  ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":83,"PERMIT_NUM":"19 239993 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"105","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115222","WARD_GRID":"W0533","APPLICATION_DATE":"2019-10-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-28","STATUS":"Approved","DESCRIPTION":"Blocks 3 & 4 BLDG L - There are 2 (two) issues to be addressed in this Alternative Solution for the townhouses. Sentence 9.9.9.1.(1) requires the exit door for the townhouse units to be not more than 1.5m above adjacent ground level and not necessary to travel down more than 1 (one) storey to reach the level served by this exit door. Secondly, Sentence 9.9.4.4.(1) requires openings in the exterior wall of adjacent fire compartments within 3m horizontally and 10m below or 5m above the exterior exit stair to be protected. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":84,"PERMIT_NUM":"19 240015 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"145","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115225","WARD_GRID":"W0533","APPLICATION_DATE":"2019-10-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-28","STATUS":"Approved","DESCRIPTION":"BLKS 3 & 4 BLDG P -There are 2 (two) issues to be addressed in this Alternative Solution for the townhouses.  Sentence 9.9.9.1.(1) requires the exit door for the townhouse units to be not more than 1.5m above adjacent ground level and not necessary to travel down more than 1 (one) storey to reach the level served by this exit door.  Secondly, Sentence 9.9.4.4.(1) requires openings in the exterior wall of adjacent fire compartments within 3m horizontally and 10m below or 5m above the exterior exit stair to be protected.  ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":85,"PERMIT_NUM":"19 240029 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"115","STREET_NAME":"CANON JACKSON","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"   ","GEO_ID":"30115221","WARD_GRID":"W0533","APPLICATION_DATE":"2019-10-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-02-28","STATUS":"Approved","DESCRIPTION":"BLKS 3 & 4 - BLDG Q -There are 2 (two) issues to be addressed in this Alternative Solution for the townhouses. Sentence 9.9.9.1.(1) requires the exit door for the townhouse units to be not more than 1.5m above adjacent ground level and not necessary to travel down more than 1 (one) storey to reach the level served by this exit door. Secondly, Sentence 9.9.4.4.(1) requires openings in the exterior wall of adjacent fire compartments within 3m horizontally and 10m below or 5m above the exterior exit stair to be protected. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":86,"PERMIT_NUM":"20 100498 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"1755","STREET_NAME":"STEELES","STREET_TYPE":"AVE","STREET_DIRECTION":"W","POSTAL":"M2R","GEO_ID":"3327203","WARD_GRID":"N0622","APPLICATION_DATE":"2020-01-03","ISSUED_DATE":null,"COMPLETED_DATE":"2020-06-04","STATUS":"Approved","DESCRIPTION":"Proposal to provide 65mm fire fighter hose valves in the exit stairwells and the required additional 65mm fire fighter valves throughout floor areas in lieu of fire hose cabinets containing 65mm and 38mm hose valves with 37mm fire hoses. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":87,"PERMIT_NUM":"20 162679 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"57","STREET_NAME":"SPADINA","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"10222988","WARD_GRID":"S1033","APPLICATION_DATE":"2020-07-02","ISSUED_DATE":null,"COMPLETED_DATE":"2020-07-22","STATUS":"Cancelled","DESCRIPTION":"The 57 Spadina project consists of a 36 storey residential tower and a 4 level basement. The building will be designed in accordance with OBC Article 3.2.2.42 (Group C, Any Height, Any Area, Sprinklered).The building will be provided with electrically supervised automatic sprinkler protection throughout as per OBC Article 3.2.2.42. Furthermore, a fire alarm system connected to a central station will be provided throughout the building.The alternative measure is based on a combination of provisions of the 2012 Ontario Building Code (OBC), the 2010 National Building Code of Canada (NBC), and NFPA 14 ¿Installation of Standpipe and Hose Systems¿ 2013 Edition.No hose cabinets will be provided, and only 65mm dia. Hose connections will be provided in all storeys. Details of the proposed standpipe system design and alternative solution include:standpipe risers and hose connections located in exit stair shafts based on OBC 3.2.9.2.(9) and 6.1.2.2. in NFPA 14conformance with OBC 3.2.9.7.(1) and (2): flow at the two hydraulically most remote hose connections of not less than 1890L/min for 30 minutes at a pressure of not less than 450kPa, and not less than 945L/min from each of the two outlets simultaneously, with the water supply supplied through the Fire Department Connection.33m of hose coverage based on 30m hose and 3m of discharge based on OBC 3.2.9.4.(2) and (5)fire extinguisher provided as required in Part 6 of the 2007 Ontario Fire Codetwo (2) 30m lengths of 38mm dia. Fire hose with nozzle will be kept at the CACF Room for possible discretionary use by fire department personnel. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":88,"PERMIT_NUM":"20 175947 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"320","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5H","GEO_ID":"10222920","WARD_GRID":"S1034","APPLICATION_DATE":"2020-08-04","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-18","STATUS":"Approved","DESCRIPTION":"Installation of 3M Fire Barrier Duct wrap 615 for protection of existing standpipe riser in southwest corner of floor area, in lieu of re-locating riser to exit stair or service shaft.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":89,"PERMIT_NUM":"21 102093 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"505","STREET_NAME":"RICHMOND","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M5V","GEO_ID":"7930870","WARD_GRID":"S1029","APPLICATION_DATE":"2021-01-08","ISSUED_DATE":null,"COMPLETED_DATE":"2021-02-24","STATUS":"Approved","DESCRIPTION":"fire wrap around standpipe to provide 1 hr rating.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":90,"PERMIT_NUM":"20 170353 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"57","STREET_NAME":"SPADINA","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M5V","GEO_ID":"10222988","WARD_GRID":"S1033","APPLICATION_DATE":"2020-07-21","ISSUED_DATE":null,"COMPLETED_DATE":"2020-08-28","STATUS":"Approved","DESCRIPTION":"Proposal for additional sprinklered windows on the North and South facing of the building","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":91,"PERMIT_NUM":"20 197485 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"36","STREET_NAME":"CHURCHILL","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M2N","GEO_ID":"499433","WARD_GRID":"N1824","APPLICATION_DATE":"2020-09-23","ISSUED_DATE":null,"COMPLETED_DATE":"2020-10-28","STATUS":"Approved","DESCRIPTION":"Enhancement of sprinkler system proposed to be provided within the two buildings.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":92,"PERMIT_NUM":"20 215959 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"65","STREET_NAME":"KING","STREET_TYPE":"ST","STREET_DIRECTION":"E","POSTAL":"   ","GEO_ID":"8313396","WARD_GRID":"S1338","APPLICATION_DATE":"2020-11-06","ISSUED_DATE":null,"COMPLETED_DATE":"2021-02-25","STATUS":"Approved","DESCRIPTION":"Alternative Solution Application for the proposed locking devices of the proposed security gates are not deemed to be electromagnetic devices as such do not satisfy to the literal OBC requirements of Sentence 3. 3. 1. 12. (10) and 3. 4. 16. (4). ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":93,"PERMIT_NUM":"20 170027 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"357","STREET_NAME":"BAY","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5H","GEO_ID":"7929475","WARD_GRID":"S1333","APPLICATION_DATE":"2020-07-20","ISSUED_DATE":null,"COMPLETED_DATE":"2020-09-08","STATUS":"Approved","DESCRIPTION":"AS-GROUND FLOOR EXIT DOOR FOR MAG LOCKInstall two maglock to existing office building","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":94,"PERMIT_NUM":"20 196582 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"492","STREET_NAME":"EGLINTON","STREET_TYPE":"AVE","STREET_DIRECTION":"E","POSTAL":"M4P","GEO_ID":"9035663","WARD_GRID":"N1537","APPLICATION_DATE":"2020-09-21","ISSUED_DATE":null,"COMPLETED_DATE":"2020-10-08","STATUS":"Approved","DESCRIPTION":"Alternative Solution addressing the dead end public corridor serving the 2nd Floor residential indoor amenity space and the 5th Floor outdoor residential amenity of the residential building. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":95,"PERMIT_NUM":"20 225412 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"11","STREET_NAME":"ORDNANCE","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M6K","GEO_ID":"3121362","WARD_GRID":"S1028","APPLICATION_DATE":"2020-12-03","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-08","STATUS":"Cancelled","DESCRIPTION":"Alternative Solution Application to use grade TP304 Sch 40 stainless steel (SS) pipe as an alternative to Type L Copper for domestic water main riser.  SS pipe proposed to be installed using victalic rigid coupling style 89.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":96,"PERMIT_NUM":"20 229280 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"30","STREET_NAME":"BOND","STREET_TYPE":"ST","STREET_DIRECTION":" ","POSTAL":"M5B","GEO_ID":"773891","WARD_GRID":"S1332","APPLICATION_DATE":"2020-12-15","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-17","STATUS":"Approved","DESCRIPTION":"FIRE SHUTTERS WILL BE USED AS CLOSURES IN THE FIRE SEPARATION AROUND THE CONVENIENCE STAIR OPENING. THE ALTERNATIVE SOLUTION IS INTENDED TO ADDRESS EXCEEDING THE MAXIMUM SIZE LIMITS PER OBC 3.1.8.6.(2) FOR OPENINGS PROTECTED BY CLOSURES (FIRE SHUTTERS) BY PROPOSING TO INSTALL CLOSELY SPACED SPRINKLERS ON THE FLOOR SIDE OF THE FIRE SHUTTERS AS A COMPENSATORY MEASURE.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":97,"PERMIT_NUM":"21 117225 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"168","STREET_NAME":"CLONMORE","STREET_TYPE":"DR","STREET_DIRECTION":" ","POSTAL":"M1N","GEO_ID":"2269119","WARD_GRID":"E2033","APPLICATION_DATE":"2021-02-17","ISSUED_DATE":null,"COMPLETED_DATE":"2021-05-05","STATUS":"Approved","DESCRIPTION":"In lieu of wired glass or glass  block as requited by OBC 9.9.4.4. (1) for protection of exposing windows onto shared exit stairs, the buildings will havee interconnected smoke alarms and be provided with a monitored sprinkler system for early warning and fire suppression to reduce and prevent fire exposure onto the exit path. The Full explanation of these features and how they meet the required performance is addressed in the accompanying report as refernced, VFT19021R01 Exit Protection Alt Sol 10 Feb2021.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":98,"PERMIT_NUM":"21 101897 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"125","STREET_NAME":"QUEENS QUAY","STREET_TYPE":" ","STREET_DIRECTION":"E","POSTAL":"M5A","GEO_ID":"30017886","WARD_GRID":"S1038","APPLICATION_DATE":"2021-01-07","ISSUED_DATE":null,"COMPLETED_DATE":"2021-03-02","STATUS":"Approved","DESCRIPTION":"Proposing to use 3M Fire Barrier Duct Wrap 615 system as an alternative fire protection for standpipes lieuof installing the piping in a rated drywall enclosure. We have included a cutsheet of the 3M fire wrap productproposed to be used and drawings highlighted to indicate the areas in which the fire wrap is proposed to beinstalled to provide the fire standpipe system with the required fire resistance rating. The proposed 3M fire wrapsystem will be installed in accordance with 3M¿s instructions as described in the attached 3M data sheet WP615-22810-2.","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":99,"PERMIT_NUM":"20 206058 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"55","STREET_NAME":"BLOOR","STREET_TYPE":"ST","STREET_DIRECTION":"W","POSTAL":"M4W","GEO_ID":"8408497","WARD_GRID":"S1136","APPLICATION_DATE":"2020-10-14","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-10","STATUS":"Approved","DESCRIPTION":"changes to exit stair no. 1","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null},{"_id":100,"PERMIT_NUM":"20 215552 ALT","REVISION_NUM":"00","PERMIT_TYPE":"AS Alternative Solution","STRUCTURE_TYPE":null,"WORK":"Alternative Solution","STREET_NUM":"15","STREET_NAME":"HOLMES","STREET_TYPE":"AVE","STREET_DIRECTION":" ","POSTAL":"M2N","GEO_ID":null,"WARD_GRID":"N1825","APPLICATION_DATE":"2020-11-05","ISSUED_DATE":null,"COMPLETED_DATE":"2020-12-15","STATUS":"Approved","DESCRIPTION":"PROPOSAL TO PROVIDE 65 MM STANDPIPE SYSTEM HOSE VALVE CONNECTIONS IN GENERAL CONFORMANCE WITH THE 2015 NATIONAL BUILDING CODE (NBC) AND THE 2013 EDITION OF NFPA 14, `STANDARD FOR INSTALLATION OF STANDPIPE AND HOSE SYSTEM¿ (AS REFERENCED BY THE NBC) IN THIS BUILDING. ","CURRENT_USE":null,"PROPOSED_USE":null,"DWELLING_UNITS_CREATED":null,"DWELLING_UNITS_LOST":null,"EST_CONST_COST":null,"ASSEMBLY":0,"INSTITUTIONAL":0,"RESIDENTIAL":0,"BUSINESS_AND_PERSONAL_SERVICES":0,"MERCANTILE":0,"INDUSTRIAL":0,"INTERIOR_ALTERATIONS":0,"DEMOLITION":0,"BUILDER_NAME":null}], "fields": [{"id": "_id", "type": "int"}, {"id": "PERMIT_NUM", "type": "text", "info": {"notes": "Last two digits of calendar year, plus IBMS-generated sequence"}}, {"id": "REVISION_NUM", "type": "text", "info": {"notes": "Two digit number identifying revisions to permit application made after permit issuance"}}, {"id": "PERMIT_TYPE", "type": "text", "info": {"notes": "Text field describing the type of permit. The less descriptive permit type names here include:\n\n* Designated Structures: Designated structure, such as communication towers, crane runways, exterior tanks and supports, pedestrian bridges, retaining walls, satellite dishes and solar collectors.\n* Partial Permits: Permits issued for parts of a building; Excavation, Shoring, Structure, etc...\n* Authority to Occupy: Partial occupancy of a building"}}, {"id": "STRUCTURE_TYPE", "type": "text", "info": {"notes": "Identifies that type of structure the application relates to."}}, {"id": "WORK", "type": "text", "info": {"notes": "Overall description of the type of work covered by application."}}, {"id": "STREET_NUM", "type": "text", "info": {"notes": "Address - street number"}}, {"id": "STREET_NAME", "type": "text", "info": {"notes": "Address - street name"}}, {"id": "STREET_TYPE", "type": "text", "info": {"notes": "Address - street type"}}, {"id": "STREET_DIRECTION", "type": "text", "info": {"notes": "Address - street direction"}}, {"id": "POSTAL", "type": "text", "info": {"notes": "First 3 digits of postal code"}}, {"id": "GEO_ID", "type": "text", "info": {"notes": "City-defined, unique identifier for Property Address"}}, {"id": "WARD_GRID", "type": "text", "info": {"notes": ""}}, {"id": "APPLICATION_DATE", "type": "date", "info": {"notes": "Date that the application was received and entered into the city's permit application management system (IBMS)"}}, {"id": "ISSUED_DATE", "type": "date", "info": {"notes": "Date that the permit was issued."}}, {"id": "COMPLETED_DATE", "type": "date", "info": {"notes": "Date work is complete and permit is cleared"}}, {"id": "STATUS", "type": "text", "info": {"notes": "Current status of application / permit"}}, {"id": "DESCRIPTION", "type": "text", "info": {"notes": "Description of work proposed in application"}}, {"id": "CURRENT_USE", "type": "text", "info": {"notes": "Use of the property at the time of application submission"}}, {"id": "PROPOSED_USE", "type": "text", "info": {"notes": "Use of the property after completion of work covered by permit"}}, {"id": "DWELLING_UNITS_CREATED", "type": "text", "info": {"notes": "Number of residential dwelling units created by completion of permit work."}}, {"id": "DWELLING_UNITS_LOST", "type": "text", "info": {"notes": "Number of residential dwelling units lost by completion of permit work."}}, {"id": "EST_CONST_COST", "type": "text", "info": {"notes": ""}}, {"id": "ASSEMBLY", "type": "float8", "info": {"notes": "Assembly Occupancy area (in sq metres) covered by permit work. (eg Restaurant, Library, Theatre)"}}, {"id": "INSTITUTIONAL", "type": "float8", "info": {"notes": "Institutional Occupancy area (in sq metres) covered by permit work (eg Hospital, Nursing Home)"}}, {"id": "RESIDENTIAL", "type": "float8", "info": {"notes": "Residential Occupancy area (in sq metres) covered by permit work"}}, {"id": "BUSINESS_AND_PERSONAL_SERVICES", "type": "float8", "info": {"notes": "Business and Personal Services Occupancy area (in sq metres) covered by permit work (Office, Bank, Medical Clinic)"}}, {"id": "MERCANTILE", "type": "float8", "info": {"notes": "Mercantile Occupancy area (in sq metres) covered by permit work (eg Department Store, Supermarket)"}}, {"id": "INDUSTRIAL", "type": "float8", "info": {"notes": "Industrial Occupancy area (in sq metres) covered by permit work (eg Warehouse, Gas Station)"}}, {"id": "INTERIOR_ALTERATIONS", "type": "float8", "info": {"notes": "Floor area (in sq metres) covered by permit work"}}, {"id": "DEMOLITION", "type": "float8", "info": {"notes": "Floor area (in sq metres) covered by permit work"}}, {"id": "BUILDER_NAME", "type": "text", "info": {"notes": "Builder associated w the permit"}}], "_links": {"start": "/api/action/datastore_search?resource_id=a96c0ba4-3026-402b-b09d-5b1268b8f810", "next": "/api/action/datastore_search?resource_id=a96c0ba4-3026-402b-b09d-5b1268b8f810&offset=100"}, "total": 437969, "total_was_estimated": false}}