Sewer Pressurized Main
Dataset description:
This dataset provides pertinent information on the general location of pressurized sewer system pipes (main and trunk), their characteristics (e.g. pipe diameter, material) and the...
Source: Sewer Pressurized Mains
Data Dictionary
- ID
- Sewer Pressurized Asset Identification
- Type
- text
- Description
Identification number assigned by the City of Toronto
- ID
- Sewer Pressurized Upstream Maintenance Hole
- Type
- text
- Description
Identification number of upstream maintenance hole
- ID
- Sewer Pressurized Downstream Maintenance Hole
- Type
- text
- Description
Identification number of downstream maintenance hole
- ID
- Sewer Pressurized Twin Number
- Type
- int4
- Description
Distinguishes pipes that have the same upstream and downstream maintenance holes.
- ID
- Sewer Pressurized Flow Type
- Type
- text
- Description
Type of medium flowing in the sewer (SAN - Sanitary, Storm - Stormwater, Combined - Combined, CSO - Combined Sewer Overflow, SCSO - Storm Plus CSO)
- ID
- Sewer Pressurized Structure Type
- Type
- text
- Description
Sewer main structure type (FM - forcemain, PSL - Pressure Sewer Line)
- ID
- Sewer Pressurized Location Description
- Type
- text
- Description
Address or location description
- ID
- Sewer Pressurized Owned By
- Type
- text
- Description
Ownership group of the pressurized sewer
- ID
- Sewer Pressurized Managed By
- Type
- text
- Description
Maintenance group of the pressurized sewer
- ID
- Sewer Pressurized Install Date
- Type
- timestamp
- Description
Approximate construction date
- ID
- Sewer Pressurized Diameter
- Type
- int4
- Description
Pipe diameter (millimetres)
- ID
- Sewer Pressurized Material
- Type
- text
- Description
Pipe material (ABS - ABS Plastic, AC - Asbestos Cement, BMP - Brick Masonry, BR - Brick, CCYL - Concrete Cylinder Pipe, CI - Cast Iron, CICL - Cast Iron Cement Lined, CMP - Corrugated Metal, CONC - Concrete - Cast-In-Place, COP - Copper, CP - Concrete (Non-Reinforced), CR - Prestressed Concrete, CT - Clay Tile, DICL - Ductile Iron Cement Line, DIP - Ductile Iron, EARGEO - Earth & Geotextile, FRP - Fiberglass Reinforced, GP - Galvanized Pipe, GRC - Glass Reinforced Cement, HDPE - High Density Polyethylene, LEAD - Lead, OTH - Other, PCCP - Pre-Stressed Concrete Cylinder, PE - Polyethylene, PP - Polypropylene, PSC - Plastic/Steel Composite, PVC - Polyvinyl Chloride, PVCO - Molecular Oriented Polyvinyl Chloride, RPM - Reinforced Plastic (Truss), SP - Steel, SPCL - Steel Pipe Cement Lined, TRR - Transite Ringtite, TRS - Transite Simplex, TTE - Transite, UNK - Unknown, VCP - Vitrified Clay, WD - Wood)
- ID
- Sewer Pressurized Main Shape
- Type
- text
- Description
Pipe cross-sectional shape (e.g. circular)
- ID
- Sewer Pressurized Measured Length
- Type
- float8
- Description
Approximate span of the selected pipes (metres)
- ID
- Sewer Pressurized Trunk Sewer
- Type
- text
- Description
Yes or No label denoting a Trunk Sewer
- ID
- Sewer Pressurized Trunk Name
- Type
- text
- Description
Identification name assigned by the City of Toronto
Additional Information
| Field | Value |
|---|---|
| Data last updated | 2025 जुन 30 |
| Metadata last updated | 2026 फेब्रुअरी 23 |
| Created | 2025 जुन 30 |
| Format | GeoJSON |
| License | License not specified |
| Datastore active | True |
| Datastore cache | {'CSV': {'4326': 'c2face06-6d83-4f8f-b34d-b5decbcec62c', '2952': '19971b18-e834-4932-8efc-54699f8de101'}, 'SHP': {'4326': '2e98112a-2c54-4cf8-936e-d9b99f6961fa', '2952': '3bd6e89c-244d-4f51-ae6b-248338c040fc'}, 'GPKG': {'4326': '86b4c735-a2c8-4985-b408-5f959daccb82', '2952': '6e201028-25d9-411a-94d2-d6218f502e19'}, 'GEOJSON': {'4326': 'f3c90988-a721-4cab-aab7-a3efa52dd2f7'}} |
| Datastore cache last update | 4 घण्टा पहिले |
| Extract job | Airflow: Integration Pipeline sewer-pressurized-mains |
| Has views | True |
| Id | bde72afc-16c8-4c19-a6c3-3114c3de7b35 |
| Is preview | True |
| Package id | 209b035f-93fa-4f72-827c-17495d75ed99 |
| Position | 0 |
| Record count | 305 |
| State | active |
| Url type | datastore |
| Vertex count | 3,349 |
| Extract Job | Airflow: Integration Pipeline sewer-pressurized-mains |
| Is Datastore Cache File? | |
| Datastore Cache |
|
| Datastore Cache Last Updated | |
| Datastore resource's ID |